Emerson elevator inverter EV3200-2S0002S

0 out of 5

Emerson elevator inverter EV3200-2S0002S Emerson drive

Model:EV3200-2S0002S

Brand:Emerson

MOQ:1 pcs

Warranty Time:1 year

Certificates:ISO9001

Emerson elevator inverter EV3200-2S0002S Emerson drive
The inverter is intended as a component for inverter system. If installed incorrectly, the inverter may present a safety hazard. The inverter uses high voltages and currents, carries a high level of…

Description

Emerson elevator inverter EV3200-2S0002S Emerson drive

 

 

Product  Models

 

Inverter model Rated input current (A) Rated capacity (kVA) Rated output current (A) Motor power(kW)
EV3200-2S0002A 2.65 0.5 1.3 0.2
EV3200-2S0002S
EV3200-2S0004A 5.3 1.0 2.5 0.4
EV3200-2S0004S

Product  Specifications

Items Subitems Specifications
Input Voltage range Single-phase AC power, 180V – 264V
Frequency range 50Hz ± 5%, 60Hz ± 5%
Output Voltage range Three-phase: OV – input voltage
Frequency range 0Hz – 128Hz
Overload ability 150% rated current for 1 minute, 180% rated current for 10 seconds
Main control functions Load motor type Three-phase AC asynchronous motor, three-phase AC synchronous motor
Modulation mode Optimized space voltage vector PWM modulation
Control algorithm Sensorless vector control, vector control with speed sensor
Operation mode Two modes: 1. The inverter operates as an inverter specially used for controlling the elevator door (elevator door control mode), 2. The inverter operates as a general purpose inverter
Frequency resolution Digital setting: 0.01 Hz
Door width auto learning The inverter operates at the auto-learnt speed, and operates in the logic procedure of close door (CD) –open door (0D)—CD—stop. After the auto-learning operation, the door width information is saved and the auto learning process is over
Auto tuning of motor’s
parameters
Purpose of auto tuning function of inverter is to obtain the motor’s parameters automatically, and these parameters will be saved automatically after the tuning process is over
Speed-adjusting range Under rated load condition, 1:100 for vector control with speed sensor; 1:50 for sensorless vector control
Operation functions OD, CDcontrol command input Terminal control mode; keypad control mode; communication control mode (reserved)
Frequency setting Set the frequency via keypad; communication control mode (reserved)
Multi-function terminal input signal External reset signal, light curtain signal, safety edge signal, OD position limiting signal, CD position limiting signal, OD speed decrease signal, CD speed decrease signal, OD prohibition signal, torque maintaining signal, slow OD and CD signals, lock signal, emergency firemen service (EFS) signal, rush hour operation enable operation, operation enable signal, auto-learning command signal
Output signal 3 relay-output: 250Vac/2A (cos0=1), 250Vac/1A (cos0=0.4), 30Vdc/1A
Display 4-digit LED display Running frequency, reference frequency, output voltage, output current, output torque, DC bus voltage, status of input terminals, status of output terminals, door-operating position (pulse number)
Protection functions Over current protection, over voltage protection, low voltage protection, over heat protection, overload protection, output phase failure protection, motor protection, motor tuning error alarm, parameter
setting error alarm, door width auto-learning error alarm, OD/CD error alarm, pulse generator (PG) error alarm, current detection circuit fault alarm, EEPROM read/write error alarm, over-speed protection
Environment Application environment Inside, free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam, water drop, and so on
Altitude Lower than 1000m. Max altitude: 3000m (deration curve should be observed at 1000m — 3000m: derated 10% for every rise of 100m)
Working temperature -10°C — + 40°C, temperature change less than 0.5°C /minute
Must be derated above 40°C: The output current must be derated 2% for every rise of 1 °C. Max temperature: 50°C
Humidity Less than 95%RH, no condensation
Vibration 3.5mm (2 — 9Hz), 10m/s2(9 — 200Hz), 15m/s2(200 — 500Hz)
Storage temperature -40°C — + 70°C
Structure Protection IP21
Cooling Forced air cooling (EV3200-250004A and EV3200-2500045)
Natural air cooling (EV3200-2S0002A and EV3200-250002S)