Emerson elevator inverter EV3200-2S0002S
Emerson elevator inverter EV3200-2S0002S Emerson drive
Model:EV3200-2S0002S
Brand:Emerson
MOQ:1 pcs
Warranty Time:1 year
Certificates:ISO9001
Emerson elevator inverter EV3200-2S0002S Emerson drive
The inverter is intended as a component for inverter system. If installed incorrectly, the inverter may present a safety hazard. The inverter uses high voltages and currents, carries a high level of…
- Description
Description
Emerson elevator inverter EV3200-2S0002S Emerson drive
Product Models
Inverter model | Rated input current (A) | Rated capacity (kVA) | Rated output current (A) | Motor power(kW) |
EV3200-2S0002A | 2.65 | 0.5 | 1.3 | 0.2 |
EV3200-2S0002S | ||||
EV3200-2S0004A | 5.3 | 1.0 | 2.5 | 0.4 |
EV3200-2S0004S |
Product Specifications
Items | Subitems | Specifications |
Input | Voltage range | Single-phase AC power, 180V – 264V |
Frequency range | 50Hz ± 5%, 60Hz ± 5% | |
Output | Voltage range | Three-phase: OV – input voltage |
Frequency range | 0Hz – 128Hz | |
Overload ability | 150% rated current for 1 minute, 180% rated current for 10 seconds | |
Main control functions | Load motor type | Three-phase AC asynchronous motor, three-phase AC synchronous motor |
Modulation mode | Optimized space voltage vector PWM modulation | |
Control algorithm | Sensorless vector control, vector control with speed sensor | |
Operation mode | Two modes: 1. The inverter operates as an inverter specially used for controlling the elevator door (elevator door control mode), 2. The inverter operates as a general purpose inverter | |
Frequency resolution | Digital setting: 0.01 Hz | |
Door width auto learning | The inverter operates at the auto-learnt speed, and operates in the logic procedure of close door (CD) –open door (0D)—CD—stop. After the auto-learning operation, the door width information is saved and the auto learning process is over | |
Auto tuning of motor’s parameters |
Purpose of auto tuning function of inverter is to obtain the motor’s parameters automatically, and these parameters will be saved automatically after the tuning process is over | |
Speed-adjusting range | Under rated load condition, 1:100 for vector control with speed sensor; 1:50 for sensorless vector control | |
Operation functions | OD, CDcontrol command input | Terminal control mode; keypad control mode; communication control mode (reserved) |
Frequency setting | Set the frequency via keypad; communication control mode (reserved) | |
Multi-function terminal input signal | External reset signal, light curtain signal, safety edge signal, OD position limiting signal, CD position limiting signal, OD speed decrease signal, CD speed decrease signal, OD prohibition signal, torque maintaining signal, slow OD and CD signals, lock signal, emergency firemen service (EFS) signal, rush hour operation enable operation, operation enable signal, auto-learning command signal | |
Output signal | 3 relay-output: 250Vac/2A (cos0=1), 250Vac/1A (cos0=0.4), 30Vdc/1A | |
Display | 4-digit LED display | Running frequency, reference frequency, output voltage, output current, output torque, DC bus voltage, status of input terminals, status of output terminals, door-operating position (pulse number) |
Protection functions | Over current protection, over voltage protection, low voltage protection, over heat protection, overload protection, output phase failure protection, motor protection, motor tuning error alarm, parameter setting error alarm, door width auto-learning error alarm, OD/CD error alarm, pulse generator (PG) error alarm, current detection circuit fault alarm, EEPROM read/write error alarm, over-speed protection |
|
Environment | Application environment | Inside, free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam, water drop, and so on |
Altitude | Lower than 1000m. Max altitude: 3000m (deration curve should be observed at 1000m — 3000m: derated 10% for every rise of 100m) | |
Working temperature | -10°C — + 40°C, temperature change less than 0.5°C /minute Must be derated above 40°C: The output current must be derated 2% for every rise of 1 °C. Max temperature: 50°C |
|
Humidity | Less than 95%RH, no condensation | |
Vibration | 3.5mm (2 — 9Hz), 10m/s2(9 — 200Hz), 15m/s2(200 — 500Hz) | |
Storage temperature | -40°C — + 70°C | |
Structure | Protection | IP21 |
Cooling | Forced air cooling (EV3200-250004A and EV3200-2500045) Natural air cooling (EV3200-2S0002A and EV3200-250002S) |