Hyundai elevator inverter HIVD900G
Hyundai elevator inverter HIVD900G
Model:HIVD900G
Brand:Hyundai
MOQ:1 pcs
Warranty Time:1 year
Certificates:ISO9001
Hyundai elevator inverter HIVD900G 30kw
Hyundai STVF5/STVF7 Inverter HIVD 900G
Power 5.5kw/7.5kw/11kw/15kw/22kw/30kw
Input: AC, 3-phase,380v-440V,50/60Hz
Output: Rated current 64A Power(kw):30kw
…
- Description
Description
Hyundai elevator inverter HIVD900G
Specifications
Hyundai STVF5/STVF7 Inverter HIVD 900G 30kw
Power 5.5kw/7.5kw/11kw/15kw/22kw/30kw
Input: AC, 3-phase,380v-440V,50/60Hz
Output: Rated current 64A Power(kw):30kw
INPUT TERMINALS 900G, 900GS( Induction Motor)
ITEM | LABEL | NAME | DESCRIPTION | REMARK | |
STVF 1&2 | STVF 3&5, FI 4 | ||||
Control Input Contact |
CM | Input Common | Common terminal of contact input terminals | CN 12 | |
UP | Up operation | ON : Up, OFF : Stop | |||
DN | Down operation | ON : Down, OFF : Stop | |||
RST | ALARM RESET | External input of Reset signal | |||
SP 1 | Sparel input | Sparel input | |||
LD | PLDL sensor input | Elevator going down is forced to stop if this signal is input | |||
INIC | Initial operation | This signal is ON when the elevator operates initial mode | |||
HOU | Upper vane sensor | Input signal of upper vane sensor | |||
HOD | Lower vane sensor | Input signal of lower vane sensor | |||
ITH | Inverter thermal sensor |
Input signal of inverter thermal sensor | |||
LU(X 1) | Selective input 1 | Multi-purpose control input selection – Multi-speed selection, – DI Torque input, – Torque Bias switch _Pre-Excitement signal, – Speed limit switch |
PLUL sensor input | ||
MU(X2) | Selective input 2 | Door zone sensor input | |||
HU(X3) | Selective input 3 | PLUH sensor input | |||
HD(X4) | Selective input 4 | PLDH sensor input | |||
MD(X5) | Selective input 5 | Sparel input | |||
AT(X6) | Selective input 6 | Auto operation signal | |||
Then-nistor Input |
THI | Motor Then-nistor Input Terminal |
Terminals for motor thermistor | TB 1 | |
TI | |||||
Encoder input |
PGM | Encoder Common | Ground common terminal of PGP, PA, PB | TB 2 | |
PGP | Encoder source | Output (+15Vdc) | |||
PA | Encoder A phase | Detection of the motor speed, Detection Terminal of the rotation direction | |||
PB | Encoder B phase |
OUTPUT TERMINALS 900G, 900GS( Induction Motor)
ITEM | LABEL | NAME | DESCRIPTION | |||
STVF 1&2 | STVF 3&5, FI 4 | |||||
Control Output Contact | CME | Transistor Output Common | Common terminal for Yl, Y2, and Y3 | |||
Y1 | Open collector output 1 | Zero Speed | Run | Allowable Load : 27Vdc 20mA (MAX) |
||
Y2 | Open collector output 2 | Speed Agree | Zero Speed | |||
Y3 | Open collector output 3 | Run | Torque Answer | |||
30B | INV. Error Output | ►30B-30C OPEN : Fault ►30B-30C CLOSE : Normal |
Contact Capacity : 220Vac 500mA |
|||
30C | INV. Error Common | |||||
Analog Output (Option Bd) | GND | Analog Common | Inverter inspection or test using Optional Board | |||
A01 | Analog output 1 | |||||
A02 | Analog output 2 | |||||
A03 | Analog output 3 | |||||
A04 | Analog output 4 |