OMRON elevator relay MY2N-GS

0 out of 5

OMRON elevator relay MY2N-GS DC24V

Model:MY2N-GS

Brand:OMRON

MOQ:10 pcs

Warranty Time:1 year

Certificates:ISO9001

OMRON elevator relay MY2N-GS DC24V
Common to all specifications
• Mechanical indicators are a standard feature on all models so that you can easily check the contact status.
• The color of the LED shows whether the coil voltage is AC or DC.
With latc…

Description

OMRON elevator relay MY2N-GS DC24V

 

 

Model Number Legend

1. Number of Poles: 2@2 poles,  4@4 poles
2. Latching Lever :
Blank@Without latching lever, I@With latching lever
3. LED Operation Indicator :
Blank@Built-in mechanical indicators
N@ LED operation indicator and built-in mechanical indicators
4. Coil Surge Absorption :
Blank@Standard models
D2@Models with built-in diodes
CR:@Models with built-in CR circuits
5. Operating Coil Voltage Display

Main unit Operating Coil

Item Rated current (mA) Coil
resistance
(S1)
Coil inductance (H) Must-operate
voltage
Must-release
voltage
Maximum
voltage
Power
consumption
(VA, W)
Rated voltage 50 Hz 60 Hz Armature
OFF
Armature ON Percentage of rated voltage
AC 12 107. 91 46 0.17 0.33 80% max. *1 30% min. *2 110% Approx. 0.9 to1.3 (at 60 Hz)
24 54. 46 180 0.69 1.
48 26. 21. 788 3. 6.
100/110 11.7/12.9 10.0/11.0 3,750 15. 25.
110/120 9.9/10.8 8.4/9.2 4,430 19. 32.
200/220 6.2/6.8 5.3/5.8 12,950 55. 94.
220/240 5.2/6.2 4.3/5.0 15,920 84. 136.
DC 6 146 (151) 41.0 (39.8) 0.17 0.33 10% min. *2 Approx. 0.9
12 72.7 (75) 165 (160) 0.73 1.
24 36.3 (37.7) 662 (636) 3. 6.
48 17.6 (18.8) 2,725
(2,560)
11. 21.0
100/110 8.7 (9.0)/9.6 (9.9) 11,440
11,
(11,100)
46. 86.
220 4. 60,394 362. 453. Approx. 0.8

 

Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for the AC rated current and +15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The values in parentheses for the rated currents and coil voltages of DC coils are for models with LED operation indicators.
5. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1.There is variation between products, but actual values are 80% max. The Relay will operate if 80% or higher of the rated voltage is applied. However, to achieve the specified characteristics, apply the rated voltage to the coil.
*2.There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the specified value.

Contact