SIEMENS contactor 3RH2122-1BB40
SIEMENS contactor 3RH2122-1BB40 for elevator
Model:3RH2122-1BB40
Brand:SIEMENS
MOQ:1 pcs
Warranty Time:1 year
Certificates:ISO9001
SIEMENS contactor 3RH2122-1BB40 for elevator
CONT.RELAY, 2NO + 2NC, DC24V
Contactor relay, 2 NO + 2 NC, 24 V DC, size S00, screw terminal
…
- Description
Description
SIEMENS contactor 3RH2122-1BB40 for elevator
Specifications
CONT.RELAY, 2NO + 2NC, DC24V
Contactor relay, 2 NO + 2 NC, 24 V DC, size S00, screw terminal
Product brand name | SIRIUS |
Product designation | Auxiliary contactor |
Product type designation | 3RH2 |
General technical data | |
Size of contactor | S00 |
Product extension | |
● Auxiliary switch | Yes |
Insulation voltage | |
● with degree of pollution 3 at AC rated value | 690 V |
Degree of pollution | 3 |
Surge voltage resistance rated value | 6 kV |
Protection class IP | |
● on the front | IP20 |
Shock resistance at rectangular impulses | |
● at DC | 10g / 5 ms, 5g / 10 ms |
Shock resistance with sine pulse | |
● at DC | 15g / 5 ms, 8g / 10 ms |
Mechanical service life (switching cycles) | |
● of contactor typical | 30,000,000 |
● of the contactor with added electronics-compatible auxiliary switch block typical | 5,000,000 |
● of the contactor with added auxiliary switch block typical | 10,000,000 |
Control circuit / Control | |
Type of voltage of the control supply voltage | DC |
Control supply voltage at DC | |
● rated value | 24 V |
Operating range factor control supply voltage rated value of magnet coil at DC | |
● initial value | 0.8 |
● Full-scale value | 1.1 |
Closing power of magnet coil at DC | 4 W |
Holding power of magnet coil at DC | 4 W |
Closing delay | |
● at DC | 30 … 100 ms |
Opening delay | |
● at DC | 7 … 13 ms |
Arcing time | 10 … 15 ms |
Auxiliary circuit | |
Number of NC contacts for auxiliary contacts 2 ● instantaneous contact 2 Number of NO contacts for auxiliary contacts 2 ● instantaneous contact 2 Identification number and letter for switching elements 22 E. Operating current at AC-12 maximum 10 A Operating current at AC-15 ● at 230 V rated value 10 A ● at 400 V rated value 3 A ● at 500 V rated value 2 A ● at 690 V rated value 1 A Operating current at 1 current path at DC-12 ● at 24 V rated value 10 A ● at 110 V rated value 3 A ● at 220 V rated value 1 A ● at 440 V rated value 0.3 A ● at 600 V rated value 0.15 A Operating current with 2 current paths in series at DC-12 ● at 24 V rated value 10 A ● at 60 V rated value 10 A ● at 110 V rated value 4 A ● at 220 V rated value 2 A ● at 440 V rated value 1.3 A ● at 600 V rated value 0.65 A |
Operating current at 1 current path at DC-13 ● at 24 V rated value 10 A ● at 110 V rated value 1 A ● at 220 V rated value 0.3 A ● at 440 V rated value 0.14 A ● at 600 V rated value 0.1 AOperating current with 2 current paths in series at DC-13 ● at 24 V rated value 10 A ● at 60 V rated value 3.5 A ● at 110 V rated value 1.3 A ● at 220 V rated value 0.9 A ● at 440 V rated value 0.2 A ● at 600 V rated value 0.1 A Operating current with 3 current paths in series at DC-13 ● at 24 V rated value 10 A ● at 60 V rated value 4.7 A ● at 110 V rated value 3 A ● at 220 V rated value 1.2 A ● at 440 V rated value 0.5 A ● at 600 V rated value 0.26 A Operating frequency at DC-13 maximum 1,000 l / h Design of the miniature circuit breaker ● for short-circuit protection of the auxiliary circuit up to 230 V C characteristic: 6 A; 0.4 kA Contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) |