SIEMENS elevator contactor 3RT1517-2BB40
SIEMENS elevator contactor 3RT1517-2BB40
Model:3RT1517-2BB40
Brand:SIEMENS
MOQ:1 pcs
Warranty Time:1 year
Certificates:ISO9001
SIEMENS elevator contactor 3RT1517-2BB40
1.Specifications : AC-3, 5.5 kW / 400 V AC-1, 22 A, 24 V DC 4-pole, 2 NO + 2 NC, Size S00 Spring-type terminal
2.Phased-out product |Successor is SIRIUS 3RT2 Preferred
3.Successor type is :3RT2517-2BB40
…
- Description
Description
SIEMENS elevator contactor 3RT1517-2BB40
1.Specifications : AC-3, 5.5 kW / 400 V AC-1, 22 A, 24 V DC 4-pole, 2 NO + 2 NC, Size S00 Spring-type terminal
2.Phased-out product |Successor is SIRIUS 3RT2 Preferred
3.Successor type is :3RT2517-2BB40
Main Specifications:
4POL.CONTACTOR, AC3: 5.5KW, 24 VDC Power contactor, AC-3 12 A, 5.5 kW / 400 V 2 NO + 2 NC 24 V DC 4-pole size S00 Spring-type terminals
Product brand name | SIRIUS |
Product designation | contactor |
Product type designation | 3RT25 |
General technical data | |
Size of contactor | S00 |
Product extension | |
● function module for communication | No |
● Auxiliary switch | Yes |
Insulation voltage | |
● of main circuit with degree of pollution 3 rated value | 690 V |
● of auxiliary circuit with degree of pollution 3 rated value | 690 V |
Surge voltage resistance | |
● of main circuit rated value | 6 kV |
● of auxiliary circuit rated value | 6 kV |
maximum permissible voltage for safe isolation | |
● between coil and main contacts acc. to EN 60947-1 | 400 V |
Protection class IP | |
● on the front | IP20 |
● of the terminal | IP20 |
Shock resistance at rectangular impulses | |
● at DC | 7.3g / 5 ms, 4.7g / 10 ms |
Shock resistance with sine pulse | |
● at DC | 11.4g / 5 ms, 7.3g / 10 ms |
Mechanical service life (switching cycles) | |
● of contactor typical | 30,000,000 |
● of the contactor with added electronics-compatible auxiliary switch block typical | 5,000,000 |
● of the contactor with added auxiliary switch block typical | 10,000,000 |
Main circuit | Operating current | ||
Number of poles for main current circuit | 4th | ● at AC-1 | |
Number of NO contacts for main contacts | 2 | up to 690 V at ambient temperature 40 ° C rated value | 22 A |
Number of NC contacts for main contacts | 2 | up to 690 V at ambient temperature 60 ° C rated value | 20 A |
Operating current | ● at AC-2 at AC-3 at 400 V | ||
● at 1 current path at DC-1 | – per NO contact rated value | 12A | |
at 24 V rated value | 20 A | – per NC contact rated value | 9A |
at 110 V rated value | 2.1 A | Minimum cross-section in main circuit | |
at 220 V rated value | 0.8 A | ● at maximum AC-1 rated value | 4 mm² |
at 440 V rated value | 0.6 A | Operating current | |
● with 2 current paths in series at DC-1 | ● at 1 current path at DC-3 at DC-5 | ||
at 24 V rated value | 20 A | – at 24 V per NC contact rated value | 20 A |
at 110 V rated value | 12 A | – at 24 V per NO contact rated value | 20 A |
at 220 V rated value | 1.6 A | – at 110 V per NC contact rated value | 0.075 A |
at 440 V rated value | 0.8 A | – at 110 V per NO contact rated value | 0.15 A |
Operating power | – at 220 V per NC contact rated value | 0.375 A | |
● at AC-2 at AC-3 | – at 220 V per NO contact rated value | 0.75 A | |
– at 230 V per NC contact rated value | 2.2 kW | ● with 2 current paths in series at DC-3 at DC-5 | |
– at 230 V per NO contact rated value | 3 kW | – at 24 V per NC contact rated value | 20 A |
– at 400 V per NC contact rated value | 4 kW | – at 24 V per NO contact rated value | 20 A |
– at 400 V per NO contact rated value | 5.5 kW | – at 110 V per NC contact rated value | 0.175 A |
– at 110 V per NO contact rated value | 0.35 A |